Category Eletta Flow

Eletta Flow

Eleta-Flow-400x209

Eletta flow monitors
used for more than sixty years

The Eletta Flow Monitors type; V-, S-, R-, A- and D-series are based on the proven and reliable differential pressure principle, using interchangeable orifice plates for different measuring ranges. They are available for threaded connections DN 15 – 40 and flanged connections DN 15 – 400 and in different material of construction such as bronze, painted cast iron and stainless steel.
They come in two measuring ratios, 1:2 and 1:5, which is indicated by the designation of the models. Flow range  are available from 0,4 l/min to 25 000 l/min.

The V1 and V15 are basic models without local indication and one micro switch set-point. It is adjustable within the flow range of the monitor. They are very robust, e.g insensitive to m...

Read More

Cerlic

When reliability counts

02 Sensors for
• Water and Waste Water
• Pulp and Paper

ACCURATE CONTROL OF THE PROCESS 

03

Slide rail assembly
for easy installation
and servicing.
The rail has fi eld
adjustable stop.
It’s easy to install
and to inspect
sensors for cleaning
and calibration

04

The fl exible, springloaded mounting bracket is designed to withstand turbulent conditions. The fi berglass telescopic rod is extendable to 4 meters (13.5 feet) and can be removed easily for inspection.

019   The automatic fl ushing device has no
moving parts and ensures minimal maintenance
andenhanced reliability. The fl ush
nozzles use water or compressed air.

SENSORS FOR PULP AND PAPER
- Optical consistency measurement

THE CTX20/25 AND CTX20/5006
FLOW-THROUGH SENSORS
enable con...

Read More

The I- and U-series

Induction and ultrasonic flow meters

FN 20XX

I-series
FN 20XX

flow-rate and volume measurement (electrically conductive liquids)
dimensions DN 6 to DN 1200
maximum pressure PN 40
maximum temperature of measured medium 150°C
accuracy of measurement ±0,2%
communication RS 485, electrical outputs

FR 10XXFR 10XX

flow-rate and volume measurement (electrically conductive liquids)
dimensions DN 6 to DN 1200
maximum pressure PN 40
maximum temperature of measured medium 150°C
accuracy of measurement ±0,5%
communication Hart, Foundation Field Bus, electrical outputs

Ultrasonic flow meters

SE 40XX

U-series
SE 40XX

flow-rate and volume measurement
single- and dual-beam versions
dimensions DN 32 to DN 1200
maximum pressure PN 40,optional PN 160
maximum temperature of measured medium 150°C
measurement accu...

Read More